| Products |
|
 |
Universal Intelligent Controller |
|
|
|

|

|
Click to enlarge image
|
Model Number |
DX Series |
Universal Intelligent Controller DX Series
- Simple Operation & Authorization Setup Function Per Each Access Code
- Big Size Graphic LCD (240x128, 5 inch)
- Error Message & Alarm Display (Operation Status Recording Devise Embedded)
- Reliable Preventative and Maintenance Function
- Solution against Noise from the External Environment
- Various Analogue Output Function
- RS485 Communication Function
- Compact & Slim Size
- Various Sensor Lineups
- IP65 Certification
DX230H for Geothermal Heat pump Controller
- Basic built-in control function for 1 cycle, 1~2 cycle
- Embedding the best control algorism for heat pump system
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)
- Transmission output (Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
DX100-120 for HVAC Controller
- Temperature & humidity control function, Max. 6 loop of independent step operating function
- Alternative operation by max. 4 compressors and 8 heaters
- Backup operating function
- Prevention from frequent starting failure occurred by low pressure hunting sing low pressure switch in compressor
- Successive starting function, pump down function and prevention from restarting function
- Control function for cold water, hot water, steam valve, SCR, damper designed for HVAC
(4~20mA PID control)
- Detection of error in temperature and humidity sensor, Alarm function, Output of equipment state (Refrigeration, Humidification, Heating and Humidification)
DX200-270 for Screw Compressor Controller
- Efficient step/stepless control, convenience for operation and inspection
- One-touch setup function (Choosing the maker -> Automatic setup according to their basic spec.)
(Bitzer, Hitachi, Refcomp, Fusheng, Hanbell, Mitsubishi, Roltec, Kobe)
- Strong timer function (Step delay, Start delay, Auto-stop delay, Restart delay, Pump down delay)
- Temperature control, Pressure control (Input temperature, Output temperature, Intake pressure control, Discharge gas temperature control and observation)
DX260 for Multi Compressor Controller
- Suitability for rack control of multi condensing unit
- Control for max. 8 compressors and 8 condensing fans (Basic : 4 compressors + 4 condensers)
- Efficient control for the number of equipment
(Setting On/Off value per individuals and/or per between steps)
- Perfect equal control (Within 1 hour difference of the total accumulated operation time)
- Pressure/temperature control
(Individual and/or interlocking control for intake pressure, discharge pressure)
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)
- Optimal function for condensing fan speed control (4~20mA PID control)
- Transmission output function (Pressure / Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol
DX230 for Recipro/Scroll Heat pump Controller
- Efficient control of recipro / scroll compressors
- Variable applications (Chiller, CDU, Spot-cooler)
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)
- Strong timer function (Start delay, Restart delay, Pump down delay)
- Temperature control, pressure control
(Input temperature, Output temperature, Intake pressure control, Discharge gas temperature control and observation)
|
|
|
|
| |
|
|
|